Quick answer: Wet wipes absorbency describes liquid uptake or capacity under defined test conditions. Liquid release describes delivery during a defined wiping or compression task. A substrate can perform well in one measurement without being the best choice for the other. Compare the substrate, lotion and finished pack as a complete system.
For a private label buyer, “highly absorbent” is an incomplete specification. A dry cleaning cloth may need to pick up a spill; a premoistened wipe must also deliver its lotion where it is needed. These are related but different product requirements.
Five Liquid-Handling Terms Buyers Should Separate
| Term | Question it answers | Useful reporting detail |
|---|---|---|
| Absorption time | How quickly does the dry material take up the test liquid? | Time, method and liquid |
| Absorption capacity | How much liquid is held after the specified procedure? | g/g or %, with drainage conditions |
| Wicking | How does liquid travel through the fabric? | Distance and time, direction and method |
| Liquid loading | How much lotion was added relative to dry substrate mass? | g liquid/g dry substrate |
| Liquid release | How much liquid leaves during the defined task? | Mass, area, force, strokes and duration |
ISO 9073-6:2025 describes methods for nonwoven absorption time, absorptive capacity and wicking. Its stated scope excludes fabrics containing superabsorbent materials. These measurements do not by themselves establish finished-wipe liquid delivery or cleaning performance.
Why High Absorbency Does Not Guarantee the Right Release
Absorption testing asks how a material takes up and holds liquid under the test procedure. A wiping assessment introduces contact, pressure, motion and a receiving surface. For procurement, the relevant question is whether the wipe delivers enough lotion for the intended task while maintaining acceptable handling and residue.
Do not choose the highest release percentage automatically. A product may wet the surface quickly yet leave too much residue, or deliver most of its lotion early in the task. A different product may retain more liquid but need additional strokes. Compare the outcome against a defined benchmark and acceptance criteria.
For makeup removal, evaluate removal and residue alongside delivery. For household or automotive cleaning, define the surface, soil and finish requirements. A liquid-transfer measurement alone is not evidence of antimicrobial performance or skin suitability.
Compare Per-Gram and Per-Sheet Values
Capacity in g/g is normalized to dry fabric mass. Capacity per wipe also depends on sheet size and GSM. For the basic weight calculation, see GSM, thickness and material weight.
Illustrative example: a 2 g dry sheet with a measured capacity of 8 g/g corresponds to 16 g of liquid under that capacity test. Loading the commercial wipe at 3 g/g adds 6 g—not 16 g. Neither number tells you how many grams will reach the surface during use. These values are invented to explain the distinction and are not RIWAY specifications.
A useful supporting example comes from Quality assessment of baby wet wipes. The authors examined two viscose/polyester spunlaces and assessed substrate properties together with lotion and wet pick-up. Their results concern those samples and conditions; they should not be turned into a universal best loading or fibre ranking.
Use the Intended Lotion for Development Comparisons
A water-based substrate test is useful for a controlled material comparison. It is not a substitute for checking the intended formulation. Record the formula version and loading, and evaluate candidate materials after a consistent equilibration period.
If one candidate uses more liquid, report that explicitly. Run one comparison with matched loading to understand the substrate difference, then a second comparison of optimized finished products if the development question requires it. Do not combine the results as if the test conditions were identical.
Keep two questions separate: “Which substrate behaves differently at the same conditions?” and “Which complete product best meets the brief?” The second may involve different GSM, loading or texture, but any resulting cost and pack changes belong in the decision.
A Practical Liquid-Release Screening Plan
The following is a proposed development framework, not an ISO test method, a regulatory requirement or a claim that RIWAY has already validated a particular protocol. The buyer and testing team should agree a repeatable method suited to the product.
- Define the task: choose the surface, contact area and intended wiping motion. Use a controlled surrogate for initial screening where appropriate.
- Identify the samples: record substrate lot, composition, GSM, dimensions, texture, formula version, loading and sample age.
- Control the procedure: fix force or pressure, contact geometry, speed, stroke count, duration and ambient conditions.
- Measure consistently: record wipe mass before and after the task and, where practical, mass gained by a clean receiving surface or collector.
- Check other mass changes: control evaporation, dripping, lint loss and liquid remaining on the fixture. Soil pickup can increase wipe mass and confound a simple before/after calculation.
- Repeat and report variation: agree replicate counts and acceptance criteria before testing. Report individual results and spread alongside averages.
Be Careful with the Release Percentage
For a clean, controlled screening task, an apparent mass-loss fraction can be calculated as:
(Wipe mass before − wipe mass after) ÷ initial liquid mass × 100%.
For example, a wipe containing 6 g of liquid that loses 1.2 g during the task has an apparent fraction of 20%. This only represents liquid delivered if evaporation, dripping, fibre loss and other pathways are sufficiently controlled. The denominator is initial liquid mass, not total wet-wipe mass. Report mass delivered per defined area as well when surface coverage is the decision of interest.
There is no universal pass percentage supplied by this guide. Agree what success looks like: cleaning result, acceptable residue, useful coverage, handling and repeatability.
Buyer Comparison Record
| Record | Candidate A | Candidate B |
|---|---|---|
| Substrate lot, fibres, GSM, size and texture | Enter specification | Enter specification |
| Formula version and liquid loading | Enter values | Enter values |
| Absorption method, liquid and capacity | Attach report | Attach report |
| Release task, force, strokes and surface | Use agreed method | Use same method |
| Delivered mass and variation | Enter results | Enter results |
| Cleaning, residue, lint and handling | Record observations | Record observations |
| Pack position and sample age | Record conditions | Record conditions |
| Decision against agreed criteria | Pass / revise | Pass / revise |
Validate the Finished Pack
A freshly prepared loose sample cannot represent every wipe in a stored pack. Include first, middle and last sheets in the agreed evaluation, and record storage orientation, time, temperature and opening history. Check moisture distribution, pooling, dispensing and closure performance.
Connect this work to your stability and packaging-compatibility plan. If the substrate, formula, loading or closure changes, review which previous results remain applicable rather than assuming the old approval covers the revised product.
How to Investigate Release Drift Between Lots
When the same specification produces a different feel, compare retained samples from the approved and suspect lots at the same pack age and storage orientation. First check dry mass and lotion loading by pack position. Then repeat the transfer test with the same surface and stroke conditions. If both lots start with similar lotion mass but transfer differs, compare the fabric construction, formula batch and test conditions before adjusting the loading target.
- Difference only at one pack position: Check moisture distribution and the pack’s storage history.
- Difference across all positions: Check substrate and formula revisions, then verify the test setup with a retained reference.
- Different transfer with the same mass loss: Check for drips, evaporation or transfer to the fixture.
Record the lot IDs and the evidence supporting any corrective action. Use the wet wipes liquid loading guide to define the mass measurements before comparing lots.
Frequently Asked Questions
Is absorbency the same as liquid loading?
No. Absorbency is a tested material behaviour. Loading is the amount of formulation added relative to dry substrate mass. See our loading-ratio guide for calculations.
Does more viscose always mean better liquid delivery?
Do not make a universal ranking from fibre percentages. Compare the actual construction and lotion under the same conditions.
Can I compare two suppliers’ absorption percentages?
Only after checking the method, test liquid, conditioning, drainage and calculation basis. Ask for the full test conditions, not only the headline value.
Does more released liquid mean better cleaning?
Not necessarily. Measure the intended cleaning outcome and residue in addition to delivered mass.
Can a hand-squeeze test be used for approval?
It can provide an informal observation, but uncontrolled force and timing make it unsuitable as the sole numerical acceptance test. Agree a repeatable procedure.
Prepare a Better Substrate Brief with RIWAY
Send your application, benchmark, target sheet size, formula direction and desired use experience. Explore substrate options, use our sample-approval checklist, or contact RIWAY to discuss comparison samples and suitable evaluation requirements.
